Micsig P130A 200 MHz Passive Probe

Micsig P130A 200 MHz passive oscilloscope probe with ground lead and coiled cable
description

The Micsig P130A is a fixed 10:1 passive oscilloscope probe with 200 MHz system bandwidth, 10 MΩ input resistance and 14.5 to 17.5 pF input capacitance. It compensates oscilloscope inputs from 5 to 30 pF, is rated for 600 V peak working voltage and has a 130 cm cable. It is a straightforward general-purpose probe for ground-referenced signals up to 200 MHz. Pertech is the exclusive Micsig distributor in Israel.

P130A highlights

  • 200 MHz system bandwidth
  • Fixed 1:10 attenuation, no 1X/10X switch
  • 10 MΩ input resistance, 14.5 to 17.5 pF input capacitance
  • Compensation range 5 to 30 pF
  • Maximum working input voltage 600 V peak or less
  • 130 cm ±1.5 cm cable, net weight under 55 g
  • Operating range -10 °C to +50 °C, humidity below 85% RH

Where the P130A fits

  • General-purpose 10X probing of digital and analog signals up to 200 MHz
  • Ground-referenced measurements on power and control boards within the 600 V peak limit
  • Shared lab benches, where a fixed 10X probe avoids attenuation mix-ups
  • Not for floating nodes: use a Micsig DP differential probe or the SigOFIT there

Models

Model Attenuation System bandwidth Input resistance Input capacitance Compensation range Max. working voltage
P130 at 1X 1:1 DC to 6 MHz 1 MΩ (oscilloscope input) not stated none <200 V DC+AC pk
P130 at 10X 1:10 DC to 200 MHz 10 MΩ (with 1 MΩ oscilloscope input) 14.5 to 17.5 pF 10 to 35 pF <600 V DC+AC pk
P130A 1:10 only 200 MHz 10 MΩ 14.5 to 17.5 pF 5 to 30 pF ≤600 Vpk

Key Specifications

Spec Value
System bandwidth 200 MHz
Attenuation 1:10
Input resistance 10 MΩ
Input capacitance 14.5 to 17.5 pF
Compensation range 5 to 30 pF
Max. working input voltage ≤600 Vpk
Cable length 130 cm ±1.5 cm
Net weight <55 g
Operating temperature -10 °C to +50 °C
Operating humidity <85% RH

Which P130A model?

The P130 and P130A share the 200 MHz 10X performance, the 10 MΩ, 14.5 to 17.5 pF input, the 600 V peak working limit and the 130 cm cable. The P130 adds a 1X position (DC to 6 MHz, below 200 V) for small, slow signals such as supply ripple, where 10X attenuation would push the signal toward the oscilloscope noise floor. The P130A is 10X only, with no switch to leave in the wrong position, and its compensation range reaches lower, 5 to 30 pF against 10 to 35 pF on the P130. For more than 200 MHz, see the Micsig MSP510 and Micsig MSP500 500 MHz probes.

Owning a Micsig

Micsig has designed oscilloscopes and probes since 2012. The company holds more than 200 patents, works under a certified quality management system, and its instruments carry CE and RoHS compliance. More than 50,000 engineers worldwide use Micsig equipment.

Micsig built the first fully touch-operated tablet oscilloscope and developed SigOFIT optical isolation for testing SiC and GaN power stages. In China it holds the national High-Tech Enterprise designation and appears on the national “Little Giant” list of specialised, innovative manufacturers. At CIAS 2025 it received the “Golden Pin” award as a high-quality supplier to the semiconductor manufacturing and test sector.

Micsig P130A in Israel

Pertech is the exclusive Micsig distributor in Israel. Warranty claims are handled through Pertech, calibration and repair are arranged through Pertech, and Pertech engineers answer setup and application questions. Some Micsig models are stocked in Israel. Contact Pertech for availability and help choosing the right P130A model.

Frequently asked questions

How does the P130 differ from the P130A?

Both give 200 MHz at 10X with 10 MΩ and 14.5 to 17.5 pF input, up to 600 V peak, on a 130 cm cable. The P130 also has a 1X setting with DC to 6 MHz bandwidth and a 200 V limit. The P130A is fixed at 10X and compensates oscilloscope inputs from 5 to 30 pF, against 10 to 35 pF for the P130.

What does the compensation range mean?

It is the span of oscilloscope input capacitance the probe can be trimmed to match, 5 to 30 pF for this probe. After connecting, adjust the probe on the oscilloscope's square-wave calibration output until the corners are flat.

Can I use a passive probe for floating measurements?

No. The ground lead of a passive probe connects to the oscilloscope ground, which is normally earthed. For floating or high-side signals use a high-voltage differential probe such as the Micsig DP series, or the Micsig SigOFIT optical isolated probe.

Which Micsig oscilloscopes is it for?

Micsig does not publish an oscilloscope compatibility list on this probe's page. Contact Pertech with your oscilloscope model and Pertech will confirm the right probe.

Who handles warranty in Israel?

Pertech, the exclusive Micsig distributor in Israel. Warranty returns go to Pertech, which deals with Micsig.

Related Micsig products at Pertech

Need a quote for the Micsig P130A 200 MHz Passive Probe? Contact Pertech.

Files and media