Micsig MSP510 500 MHz Passive Probe

Micsig MSP510 500 MHz passive oscilloscope probe with ground lead, probe tip cover and coiled cable
description

The Micsig MSP510 is a 10:1 passive oscilloscope probe rated at 500 MHz, with a rise time of 800 ps or less, 10 MΩ input resistance and 10.5 pF ±0.5 pF input capacitance. Its adjustable capacitor matches oscilloscope inputs between 4 and 24 pF, it is rated for working voltage below 600 Vpk, and it has a 132 cm cable. It is a general-purpose probe for ground-referenced signals where 500 MHz probe bandwidth is enough. Pertech is the exclusive Micsig distributor in Israel.

MSP510 highlights

  • 500 MHz bandwidth, rise time 800 ps or less
  • 10:1 attenuation with 10 MΩ input resistance
  • Input capacitance 10.5 pF ±0.5 pF, a tight tolerance
  • Compensation range 4 to 24 pF
  • Maximum working input voltage below 600 Vpk
  • 132 cm ±1.5 cm cable, net weight under 53 g
  • Operating range -10 °C to +50 °C, humidity below 85% RH

Where the MSP510 fits

  • Clock, data and control lines on embedded and digital boards, where an 800 ps rise time keeps edges readable
  • Analog signals and supply rails referenced to circuit ground, within the 600 Vpk working limit
  • A spare or added 10X probe for a multi-channel oscilloscope setup
  • Not for floating nodes: use a Micsig DP differential probe or the SigOFIT there

Models

ModelBandwidthRise timeInput capacitanceCompensation rangeCable length
MSP510500 MHz≤800 ps10.5 pF ±0.5 pF4 to 24 pF132 cm ±1.5 cm
MSP500500 MHz≤700 ps12 pF ±1.5 pFnot stated120 cm ±1.5 cm

Key Specifications

SpecValue
Bandwidth500 MHz
Rise time≤800 ps
Attenuation1:10
Input resistance10 MΩ
Input capacitance10.5 pF ±0.5 pF
Compensation range4 to 24 pF
Max. working input voltage<600 Vpk
Cable length132 cm ±1.5 cm
Net weight<53 g
Operating temperature-10 °C to +50 °C
Operating humidity<85% RH

Which MSP510 model?

Both are 10:1, 500 MHz, 10 MΩ probes for up to 600 Vpk working voltage, and both weigh under 53 g. The MSP510 has lower and more tightly specified input capacitance (10.5 pF ±0.5 pF against 12 pF ±1.5 pF), a stated compensation range of 4 to 24 pF and a longer 132 cm cable. The MSP500 has the faster stated rise time, 700 ps or less against 800 ps or less, and a 120 cm cable. If your oscilloscope’s input capacitance is known, the MSP510’s published compensation range makes it easy to confirm a match.

Owning a Micsig

Micsig has designed oscilloscopes and probes since 2012. The company holds more than 200 patents, works under a certified quality management system, and its instruments carry CE and RoHS compliance. More than 50,000 engineers worldwide use Micsig equipment.

Micsig built the first fully touch-operated tablet oscilloscope and developed SigOFIT optical isolation for testing SiC and GaN power stages. In China it holds the national High-Tech Enterprise designation and appears on the national “Little Giant” list of specialised, innovative manufacturers. At CIAS 2025 it received the “Golden Pin” award as a high-quality supplier to the semiconductor manufacturing and test sector.

Micsig MSP510 in Israel

Pertech is the exclusive Micsig distributor in Israel. Warranty claims are handled through Pertech, calibration and repair are arranged through Pertech, and Pertech engineers answer setup and application questions. Some Micsig models are stocked in Israel. Contact Pertech for availability and help choosing the right MSP510 model.

Frequently asked questions

How does the MSP510 differ from the MSP500?

Both are 10:1, 500 MHz, 10 MΩ probes rated below 600 V peak. The MSP510 has lower input capacitance (10.5 pF plus or minus 0.5 pF), a stated 4 to 24 pF compensation range and a 132 cm cable. The MSP500 has a faster stated rise time (700 ps or less, against 800 ps or less), 12 pF plus or minus 1.5 pF input capacitance and a 120 cm cable.

What does the compensation range mean?

It is the span of oscilloscope input capacitance the probe can be trimmed to match, 4 to 24 pF for this probe. After connecting, adjust the probe on the oscilloscope's square-wave calibration output until the corners are flat.

Can I use a passive probe for floating measurements?

No. The ground lead of a passive probe connects to the oscilloscope ground, which is normally earthed. For floating or high-side signals use a high-voltage differential probe such as the Micsig DP series, or the Micsig SigOFIT optical isolated probe.

Which Micsig oscilloscopes is it for?

Micsig does not publish an oscilloscope compatibility list on this probe's page. Contact Pertech with your oscilloscope model and Pertech will confirm the right probe.

Who handles warranty in Israel?

Pertech, the exclusive Micsig distributor in Israel. Warranty returns go to Pertech, which deals with Micsig.

Related Micsig products at Pertech

Need a quote for the Micsig MSP510 500 MHz Passive Probe? Contact Pertech.