The Micsig P130 is a passive oscilloscope probe with two attenuation settings. At 10X it gives DC to 200 MHz system bandwidth, 10 MΩ input resistance (with a 1 MΩ oscilloscope input) and up to 600 V DC plus AC peak; at 1X it passes DC to 6 MHz at up to 200 V peak with the oscilloscope’s own 1 MΩ input. The 10X compensation range is 10 to 35 pF and the cable is 130 cm. It suits benches that move between low-level and general-purpose measurements. Pertech is the exclusive Micsig distributor in Israel.
P130 highlights
- Two settings: 1X and 10X attenuation
- 10X: DC to 200 MHz system bandwidth, 10 MΩ input resistance with a 1 MΩ oscilloscope input
- 10X: input capacitance 14.5 to 17.5 pF, compensation range 10 to 35 pF
- 10X: maximum working voltage below 600 V DC+AC peak
- 1X: DC to 6 MHz, input resistance equals the oscilloscope’s 1 MΩ, below 200 V DC+AC peak
- 130 cm ±1.5 cm cable, net weight under 55 g
- Operating range -10 °C to +50 °C, humidity below 85% RH
Where the P130 fits
- Low-level, low-frequency signals at 1X, such as ripple and noise on supply rails, where full signal amplitude reaches the oscilloscope
- General-purpose 10X probing of digital and analog signals up to 200 MHz
- Teaching and lab benches where one probe has to cover both cases
- Not for floating nodes: use a Micsig DP differential probe or the SigOFIT there
Models
| Model | Attenuation | System bandwidth | Input resistance | Input capacitance | Compensation range | Max. working voltage |
|---|---|---|---|---|---|---|
| P130 at 1X | 1:1 | DC to 6 MHz | 1 MΩ (oscilloscope input) | not stated | none | <200 V DC+AC pk |
| P130 at 10X | 1:10 | DC to 200 MHz | 10 MΩ (with 1 MΩ oscilloscope input) | 14.5 to 17.5 pF | 10 to 35 pF | <600 V DC+AC pk |
| P130A | 1:10 only | 200 MHz | 10 MΩ | 14.5 to 17.5 pF | 5 to 30 pF | ≤600 Vpk |
Key Specifications
| Spec | Value |
|---|---|
| Attenuation | 1X / 10X |
| System bandwidth | 1X: DC to 6 MHz; 10X: DC to 200 MHz |
| Input resistance | 1X: 1 MΩ (oscilloscope input); 10X: 10 MΩ with a 1 MΩ oscilloscope input |
| Input capacitance (10X) | 14.5 to 17.5 pF |
| Compensation range (10X) | 10 to 35 pF |
| Max. working input voltage | 1X: <200 V DC+AC pk; 10X: <600 V DC+AC pk |
| Cable length | 130 cm ±1.5 cm |
| Net weight | <55 g |
| Operating temperature | -10 °C to +50 °C |
| Operating humidity | <85% RH |
Which P130 model?
The P130 and P130A share the 200 MHz 10X performance, the 10 MΩ, 14.5 to 17.5 pF input, the 600 V peak working limit and the 130 cm cable. The P130 adds a 1X position (DC to 6 MHz, below 200 V) for small, slow signals such as supply ripple, where 10X attenuation would push the signal toward the oscilloscope noise floor. The P130A is 10X only, with no switch to leave in the wrong position, and its compensation range reaches lower, 5 to 30 pF against 10 to 35 pF on the P130. For more than 200 MHz, see the Micsig MSP510 and Micsig MSP500 500 MHz probes.
Owning a Micsig
Micsig has designed oscilloscopes and probes since 2012. The company holds more than 200 patents, works under a certified quality management system, and its instruments carry CE and RoHS compliance. More than 50,000 engineers worldwide use Micsig equipment.
Micsig built the first fully touch-operated tablet oscilloscope and developed SigOFIT optical isolation for testing SiC and GaN power stages. In China it holds the national High-Tech Enterprise designation and appears on the national “Little Giant” list of specialised, innovative manufacturers. At CIAS 2025 it received the “Golden Pin” award as a high-quality supplier to the semiconductor manufacturing and test sector.
Micsig P130 in Israel
Pertech is the exclusive Micsig distributor in Israel. Warranty claims are handled through Pertech, calibration and repair are arranged through Pertech, and Pertech engineers answer setup and application questions. Some Micsig models are stocked in Israel. Contact Pertech for availability and help choosing the right P130 model.
Frequently asked questions
How does the P130 differ from the P130A?
Both give 200 MHz at 10X with 10 MΩ and 14.5 to 17.5 pF input, up to 600 V peak, on a 130 cm cable. The P130 also has a 1X setting with DC to 6 MHz bandwidth and a 200 V limit. The P130A is fixed at 10X and compensates oscilloscope inputs from 5 to 30 pF, against 10 to 35 pF for the P130.
When should I use the 1X setting?
For small signals below about 6 MHz, such as rail ripple, where 10X attenuation would cut the signal tenfold. At 1X the bandwidth drops to DC to 6 MHz and the limit is 200 V peak, and the circuit sees the oscilloscope's 1 MΩ input directly.
What does the compensation range mean?
It is the span of oscilloscope input capacitance the probe can be trimmed to match, 10 to 35 pF at 10X for this probe. After connecting, adjust the probe on the oscilloscope's square-wave calibration output until the corners are flat.
Can I use a passive probe for floating measurements?
No. The ground lead of a passive probe connects to the oscilloscope ground, which is normally earthed. For floating or high-side signals use a high-voltage differential probe such as the Micsig DP series, or the Micsig SigOFIT optical isolated probe.
Which Micsig oscilloscopes is it for?
Micsig does not publish an oscilloscope compatibility list on this probe's page. Contact Pertech with your oscilloscope model and Pertech will confirm the right probe.
Who handles warranty in Israel?
Pertech, the exclusive Micsig distributor in Israel. Warranty returns go to Pertech, which deals with Micsig.
Related Micsig products at Pertech
- Micsig P130A 200 MHz passive probe
- Micsig MSP510 500 MHz passive probe
- Micsig DP 100 MHz high-voltage differential probe
- Micsig DP 200 MHz high-voltage differential probe
- Micsig DP 300 MHz high-voltage differential probe
- Micsig SigOFIT Gen 3 optical isolated probe
- Micsig CP high-frequency current probe
Need a quote for the Micsig P130 1X/10X Passive Probe? Contact Pertech.
Related Micsig products in Israel: all Micsig oscilloscopes and probes, P130A passive probe, MSP500 passive probe and STO Gen 6 tablet oscilloscope.