Micsig SigOFIT MOIP Series
Offers bandwidths from 100 MHz to 1 GHz with common-mode rejection ratios up to 180 dB. Differential voltage ranges from ±25V to ±6250V, depending on the attenuation tip. Ideal for power device evaluation, EMI troubleshooting, and high-voltage applications.
An optical-fiber isolated probe is a specialized sensor that uses optical fiber technology to provide electrical isolation between the probe and the measurement system. Here’s a breakdown of its use and purpose:
🔌 Main Purpose: Electrical Isolation
- The probe isolates the measurement system (like an oscilloscope or data acquisition system) from the high-voltage or noisy environment where the measurement is being taken.
- This protects sensitive equipment and users from potentially dangerous voltages or electrical surges.
📡 How It Works
- The probe converts electrical signals into optical signals, transmits them via optical fiber, and then converts them back to electrical signals at the receiving end.
- Since light signals aren’t affected by electromagnetic interference or ground loops, this ensures a clean, interference-free measurement.
🛠️ Common Applications
- High-Voltage Environments
- Power electronics testing (e.g., IGBTs, inverters, motor drives)
- HVDC transmission systems
- Medical Equipment
- Patient monitoring systems where patient safety requires isolation
- Industrial Automation
- Measuring signals in systems with multiple ground potentials
- RF and EMC Testing
- Reduces interference and ground loop issues during sensitive signal measurements
Bandwidth:100MHz-1GHz
Common Mode Voltage:85kVpk
DC Accuracy:1%
CMRR:up to 180dB
Interface: BNC
Features
- Present True Signal
- Highest Accuracy
- Best Probe for Third-Gen Semiconductor
- Safe to Test GaN
- Real Optical Isolation Technology
- Wide Measurement Range
- Efficient & Affordable
-
Applications
* Design of motor drive, power converter, electronic ballast
* Design of GaN, SiC, IGBT Half/Full bridge devices
* Design of inverter, UPS and switching power supply
* Safety test for high voltage, high bandwidth applications
* Power device evaluation
* Current shunt measurements
* EMI & ESD troubleshooting
* Floating measurements
Key Specifications
Model* | MOIP100P | MOIP200P | MOIP350P | MOIP500P | MOIP800P | MOIP1000P |
---|---|---|---|---|---|---|
Bandwidth | 100MHz | 200MHz | 350MHz | 500MHz | 800MHz | 1GHz |
Rise Time | ≤3.5ns | ≤1.75ns | ≤1ns | ≤700ps | ≤438ps | ≤350ps |
CMRR | DC: 180dB 100MHz: 128dB |
DC: 180dB 200MHz: 122dB |
DC: 180dB 350MHz: 118dB |
DC: 180dB 500MHz: 114dB |
DC: 180dB 800MHz: 110dB |
DC: 180dB 1GHz: 108dB |
Differential Voltage Range | Standard OP20(MMCX), ±25V Optional OP50(MMCX), ±62.5V Optional OP200(MCX), ±250V Optional OP1000(MCX), ±1250V Optional OP2000(MCX), ±2500V Optional OP5000(LCX), ±6250V |
Standard OP20(MMCX), ±25V Optional OP50(MMCX), ±62.5V Optional OP200(MCX), ±250V Standard OP1000(MCX), ±1250V Optional OP2000(MCX), ±2500V Optional OP5000(LCX), ±6250V |
Optional OP20(MMCX), ±10V Standard OP50(MMCX), ±25V Optional OP100(MMCX), ±50V Standard OP2000(MCX), ±1000V Optional OP5000(MCX), ±2500V Optional OP10000(LCX), ±5000V |
|||
Noise | <0.45mVrms | |||||
DC Gain Accuracy | 1% | |||||
Common Mode Voltage Range | 85kVpk | |||||
Interface | Universal BNC |
* Note: Current model names updated on March 20, 2024, previous model names referred as MOIP01P, and OIP100 (e.g. 100MHz bandwidth).