- Frequency range: 9 kHz – 8.5 GHz and 100 kHz – 26.5 GHz
- Frequency resolution: 1 Hz
- Setting Range of Output Level: -55 ~ +10 dBm
- Dynamic Range: 125 dB
- 2/4-ports: S-parameters, Balance Measurements, Time Domain
- Measure: Q-factor, bandwidth and Insertion Loss
- Power source calibration compatible with R&S NRPxxA/AN and Keysight U2000A/B series USB power meters
- Compatible with several manufacturers ECal kits (contact us for more information)
Product Overview
The SIGLENT SNA5000A series of Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz and 100 kHz to 26.5 GHz, which support 2/4-port scattering parameter, differential-parameter, and time-domain parameter measurements. The SNA5000A series of VNAs are effective instrumentation for determining the Q-factor, bandwidth, and insertion loss of a filter, They feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. The VNAs have five sweep types: Linear-Frequency mode, Log-Frequency mode, Power-Sweep mode, CW-Time mode, and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response, and Enhanced Response for increased flexibility in R&D and manufacturing applications.
Frequency Range | Ports | Dynamic Range | Trace Noise | Range of Output | |
---|---|---|---|---|---|
SNA5002A | 9 kHz~4.5 GHz | 2 | 125 dB | 0.003 dB rms,0.03° rms | -55 ~ +10 dBm |
SNA5004A | 9 kHz~4.5 GHz | 4 | 125 dB | 0.003 dB rms,0.03° rms | -55 ~ +10 dBm |
SNA5012A | 9 kHz~8.5 GHz | 2 | 125 dB | 0.003 dB rms,0.03° rms | -55 ~ +10 dBm |
SNA5014A | 9 kHz~8.5 GHz | 4 | 125 dB | 0.003 dB rms,0.03° rms | -55 ~ +10 dBm |
SNA5022A | 100 kHz~13.5 GHz | 2 | 125 dB | 0.003 dB rms,0.03° rms | -55 dBm ~ +10 dBm |
SNA5032A | 100 kHz~26.5 GHz | 2 | 125 dB | 0.003 dB rms,0.03° rms | -55 dBm ~ +10 dBm |
Key Features
- Frequency range: 9 kHz – 8.5 GHz and 100 kHz – 26.5 GHz
- Frequency resolution: 1 Hz
- Level resolution: 0.05 dB
- Range of IFBW: 10 Hz~3 MHz
- Setting range of output level:
-55 dBm ~ +10 dBm - Dynamic range: 125 dB
- Types of calibration: Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, Full-three port calibration, Full-four port calibration, TRL calibration
- Types of measurement: Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter removal/insertion, spectrum analysis frequency offset, scalar mixer measurement
- Internal Bias-Tee connections
- Interface: LAN, USB Device, USB Host (USB-GPIB)
- Remote control: SCPI/ Labview/ IVI based on USB-TMC / VXI-11 / Socket /Telnet / WebServer
- 1-inch touch screen
- Video output: HDMI