SNA5000A Series Vector Network Analyzer

description

  • Frequency range: 9 kHz – 8.5 GHz and 100 kHz – 26.5 GHz
  • Frequency resolution: 1 Hz
  • Setting Range of Output Level: -55 ~ +10 dBm
  • Dynamic Range: 125 dB
  • 2/4-ports: S-parameters, Balance Measurements, Time Domain
  • Measure: Q-factor, bandwidth and Insertion Loss
  • Power source calibration compatible with R&S NRPxxA/AN and Keysight U2000A/B series USB power meters
  • Compatible with several manufacturers ECal kits (contact us for more information)

Product Overview

The SIGLENT SNA5000A series of Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz and 100 kHz to 26.5 GHz, which support 2/4-port scattering parameter, differential-parameter, and time-domain parameter measurements. The SNA5000A series of VNAs are effective instrumentation for determining the Q-factor, bandwidth, and insertion loss of a filter, They feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation, and adapter removal/insertion adjustments. The VNAs have five sweep types: Linear-Frequency mode, Log-Frequency mode, Power-Sweep mode, CW-Time mode, and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response, and Enhanced Response for increased flexibility in R&D and manufacturing applications.

Frequency Range Ports Dynamic Range Trace Noise Range of Output
SNA5002A 9 kHz~4.5 GHz 2 125 dB 0.003 dB rms,0.03° rms -55 ~ +10 dBm
SNA5004A 9 kHz~4.5 GHz 4 125 dB 0.003 dB rms,0.03° rms -55 ~ +10 dBm
SNA5012A 9 kHz~8.5 GHz 2 125 dB 0.003 dB rms,0.03° rms -55 ~ +10 dBm
SNA5014A 9 kHz~8.5 GHz 4 125 dB 0.003 dB rms,0.03° rms -55 ~ +10 dBm
SNA5022A 100 kHz~13.5 GHz 2 125 dB 0.003 dB rms,0.03° rms -55 dBm ~ +10 dBm
SNA5032A 100 kHz~26.5 GHz 2 125 dB 0.003 dB rms,0.03° rms -55 dBm ~ +10 dBm

Key Features

  • Frequency range: 9 kHz – 8.5 GHz and 100 kHz – 26.5 GHz
  • Frequency resolution: 1 Hz
  • Level resolution: 0.05 dB
  • Range of IFBW: 10 Hz~3 MHz
  • Setting range of output level:
    -55 dBm ~ +10 dBm
  • Dynamic range: 125 dB
  • Types of calibration: Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, Full-three port calibration, Full-four port calibration, TRL calibration
  • Types of measurement: Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter removal/insertion, spectrum analysis frequency offset, scalar mixer measurement
  • Internal Bias-Tee connections
  • Interface: LAN, USB Device, USB Host (USB-GPIB)
  • Remote control: SCPI/ Labview/ IVI based on USB-TMC / VXI-11 / Socket /Telnet / WebServer
  • 1-inch touch screen
  • Video output: HDMI

 

Files and media

upbtn